Why It Failed
Well Diagnostics & Pump Controls in Western NC
Well diagnostics start when a pump cycles, there is no water, or water comes and goes. Case Water Systems tests the switch, controls, tank and pump, then explains what we found.
Fully licensed and insured. Work is performed onsite by a licensed contractor.
Pump acting up?
Start with the controls, then look past them
Call us for no water, a pump that keeps cycling, a pump that runs but does not deliver water, pressure that comes and goes, or control problems that keep coming back. Tell us when it started and whether every faucet is affected. More than one part can cause the same symptom, so swapping the pump without testing may not fix it.

Submersible pumps come in two common types. A two-wire pump has its starting components built into the motor, so there is no control box. A three-wire pump uses a control box above ground that holds the start capacitor, run capacitor if present, and a start relay. When a three-wire pump will not start, the problem may be in the control box, which is much easier to repair than pulling the pump. That is one of the first things we check.
With the right meters we can learn a lot about a submersible motor without pulling it. Winding resistance tells us whether the motor is open or shorted. An insulation test tells us whether the wire or motor has a fault to ground. Current draw while the pump runs shows whether the motor is working too hard or too little. Together, these help tell a bad motor from a bad wire splice, a bad control or a well that is running low on water.
What to check before we come out
- Is it every faucet, or just one?
- Look at the well pump breaker. Reset it once; if it trips again, leave it off.
- Read the gauge by the pressure tank and note the number.
- Listen near the tank and switch: clicking, humming, or a pump that never stops.
- If you have a constant pressure controller, write down any fault code on the display.
- Think back: a storm, a power blip, a dry spell or recent work on the well.
Questions to ask before anyone replaces parts
- What did you test, and what did the readings show? Voltage, amp draw, winding resistance and insulation tell a bad motor from a bad splice or control.
- Have the control box, switch and tank been ruled out? They’re cheaper and easier than the pump.
- Is the well keeping up? A pump that outruns the well looks like a pump problem.
- Was it lightning? If so, ask about grounding and surge protection so it doesn’t happen again.
Constant pressure drives, lightning and problems that are not electrical
Variable speed drives, also called constant pressure controllers, adjust the pump speed to keep pressure steady. When they fail, they often show a fault code. Those codes may point to the drive itself, the pump, the wiring, or the well running dry. We service these systems and can tell whether the drive or the pump is the problem. See constant pressure systems.
Lightning is a real risk for well pumps in the mountains. A nearby strike can damage the pump motor, the control box, the pressure switch or the drive. When we find damage that points to a surge, we look at grounding and whether a surge arrester makes sense at the well.
A tank problem, a leaking water line, a plumbing restriction or a change in available water can produce similar symptoms. We review observed pressure and delivery together. See pressure tank replacement and low-pressure diagnostics. Pump removal or a down-hole camera may be discussed when appropriate; neither is assumed in every visit.
The repair is quoted after diagnosis, before any work starts. We leave you with what we measured, so the next time something goes wrong there is a record to compare against.
Water level, recovery and when a longer flow test helps
Some problems are not electrical at all. A pump that runs but delivers little water, or that shuts off on a low-pressure switch, may be outrunning the well. We check how fast the well recovers and whether storage or a change to the pump setup would help. If the water quits after heavy use and comes back after a rest, see why a well runs out of water. A storage tank can solve many low-yield problems.
A standard well inspection already includes a sustained pumping and flow-rate test, static and pumping water-level measurements, and drawdown and recovery testing. Those figures show how the well performed during that visit. They are not a promise of the same yield in every season.
Mountain wells often give less in a dry fall than in a wet spring. When you need a longer, separately quoted flow test, for example because you are buying a home and want more data, or you are adding a bathroom, a rental unit, livestock or irrigation, we can do that as well. See well flow and yield testing.
For the visit, give us the address, any equipment history and photos of the accessible controls if you have them. Arrange access to the pressure equipment and wellhead. Do not open electrical components to collect information, and do not repeatedly reset a breaker that trips. If the house has no water, see emergency well service. Arrival depends on the schedule, weather and how remote the property is.
Common well diagnostics questions
What should I check before calling about a well problem?
See whether every faucet is affected, check the well pump breaker and reset it only once, read the pressure gauge, listen for clicking or a pump that won’t stop, and write down any controller fault code. Then call (828) 222-4160 with what you found.
Does a tripped breaker prove the pump has failed?
No. Several faults can cause a trip, including a short in the wire, a bad control box or a failing motor. Try the breaker once. If it trips again, leave it off and request an assessment.
Can you replace a pressure switch or control box?
We assess the component and whether it matches the system, then discuss replacement when the findings support it. A different controller is not automatically an upgrade.
Can you test how much water my well produces?
A standard well inspection includes a sustained pumping and flow-rate test, water-level measurements, and drawdown and recovery testing. Those numbers describe how the well performed during the visit; they are not a long-term yield guarantee. When you need a longer, separately quoted flow test, for example because you are adding demand, we can do that too.
If the well itself is the problem, can you still help?
Yes. Once a well is in place, we handle the hookup: the pump, pressure tank, controls and water line. Need a new well drilled? We can refer you to a driller we trust, then handle the pump, pressure tank and water system from there.
Do you offer well diagnostics in my area?
We diagnose private well problems across Western North Carolina, including Asheville, Candler, Hendersonville, Waynesville, Sylva and the surrounding counties. Call (828) 222-4160 with the property address.
Want the system tested before anyone replaces a pump?
Send the address and what the well is doing. We’ll call or text to confirm a time. If you have no water, call (828) 222-4160.