Well Systems & Pump Repair
What causes water pressure tank problems on a well?
Well pressure tank problems in Asheville and Western NC often show up as pulsing shower pressure, or a pump that clicks on every time somebody rinses a glass. The pressure tank is the first thing we look at. It is one of the cheaper parts of a well system and one of the most common reasons a good pump gets worn out early. A leak or a bad check valve can look the same, so we test the tank, switch and valves before recommending a replacement.
Signs the pressure tank is the problem
- The pump clicks on and off every few seconds while water runs.
- Pressure swings up and down during a shower.
- The gauge needle jumps fast between low and high.
- Water spits from the air valve on top of the tank.
- The tank sounds or feels full of water when you tap the top.
More on tanks is on our pressure tank replacement page.
What the tank is actually doing

Most tanks in mountain homes are bladder or diaphragm tanks. Inside the steel shell a rubber bladder holds the water, with a cushion of compressed air on the other side. When the pump runs, it pushes water into the bladder; when you open a faucet, the air pushes the water back out so you get pressure without the pump starting.
The pressure switch watches this. On a lot of systems it turns the pump on around 30 or 40 psi and off around 50 or 60, but check the label or the gauge readings you see on a normal day. The tank is there so the pump is not starting every few seconds all day.
How to tell a charge problem from a failed bladder
If the pump clicks on every time a tap opens, or shower pressure pulses, start with the air charge. Check air pressure at the tank valve with the system drained. If the pre-charge is just low, setting it correctly can fix it. If water spits out of the air valve, or the tank is heavy and solid when you rap it, the bladder is torn or the tank is waterlogged, and adding air will not last. See pressure tank replacement.
If the pump runs long or will not shut off, the tank may not be the problem. That can be a leak, a switch problem, or a well running short. See pressure switch repair and why a well runs out of water. Short cycling is worth fixing quickly because it wears out the switch and the pump. Outdoor tanks, and tanks in unheated pump houses, also need freeze protection.
Questions we get about this
How do I know if my well pressure tank is bad?
Common signs are a pump that starts and stops every few seconds, shower pressure that pulses, a tank that feels heavy and solid when you rap it, or water coming out of the air valve. A failed switch or a leak can cause similar symptoms, so we test the system before replacing the tank.
Can I just add air to a waterlogged tank?
If the tank has only lost its air charge, setting the pre-charge correctly can fix it. If the bladder is torn, water comes out of the air valve and adding air will not last. That tank needs to be replaced.
What should the air pressure be in a well pressure tank?
With the water drained off, the air pre-charge is usually set about 2 psi below the pump’s cut-in pressure. Check the label on the tank and the cut-in setting on the switch; we confirm both on the visit.
Is short cycling bad for the pump?
Yes. Every pump start hits the motor with a surge of current. A tank that has failed or lost its charge makes the pump start far more often than it should, which shortens pump and switch life.
Why does my pump turn on when no one is using water?
That can be a leak in the house or in the buried line, a running toilet, a leaking check valve, or a switch problem. It is not always the tank. We test before we replace anything.
Why is my pressure tank not filling with water?
If the tank will not fill and the pressure gauge stays low, the pump may not be moving water, a valve may be closed, a line may have opened up, or the well may have run short. If the pump is running and the needle will not climb, shut the breaker off so the motor is not running dry, then call. For a completely dry house, see what to do when your well has no water.
Think the tank is the problem?
Tell us what the water is doing and how the gauge behaves. We’ll call or text to confirm a time. If you have no water, call (828) 222-4160.